Get the latest price?

C Series 94 kVA DG Set 50Hz

  • C Series 94 kVA DG Set 50Hz Manufacturers, C Series 94 kVA DG Set 50Hz Factory, Supply C Series 94 kVA DG Set 50Hz
  • C Series 94 kVA DG Set 50Hz Manufacturers, C Series 94 kVA DG Set 50Hz Factory, Supply C Series 94 kVA DG Set 50Hz
  • C Series 94 kVA DG Set 50Hz Manufacturers, C Series 94 kVA DG Set 50Hz Factory, Supply C Series 94 kVA DG Set 50Hz
  • C Series 94 kVA DG Set 50Hz Manufacturers, C Series 94 kVA DG Set 50Hz Factory, Supply C Series 94 kVA DG Set 50Hz
C Series 94 kVA DG Set 50Hz
  • Bidirection Power
  • Cummins China
  • 30 - 45 days
  • 1000 sets

C Series 94 kVA DG Set 50Hz is powered by Cummins diesel engine 6BT5.9-G1 which has many features as compact size, low fuel consumption, low vibration, low noise, low maintenance, high parts commonality & long service life, providing powered diesel gensets with great transient response, wide application, high economic efficiency & high reliability and meeting the small or medium power (prime or standby) demand on residential use, small shops, small projects and other fields. Cummins serves customers with International Warranty Services (IWS). Introduction for selection criteria for dg genset.

Selection criteria for dg genset

The main factors that should be considered in the selection of diesel engine generator sets

The factors that should be considered in the selection of dg set are mainly mechanical and electrical performance, purpose of the unit, load capacity and range of change, automation, silent box, and mobile power genset station.

1. The purpose of the unit. Since diesel engine generator sets can be used in three situations: common use, standby and emergency power, the requirements for diesel engine generator sets are different for different purposes.

2. Load capacity. The load capacity and load variation range should be selected according to different purposes, and the single-unit capacity of the diesel engine generator set and the capacity of the standby diesel generator set should be determined.

3. The operating environment conditions of the unit (mainly refer to the altitude and climatic conditions).

4. The unit is designed with an advanced control system and a dedicated program controller. In the event of a mains power loss, phase loss, or undervoltage, the unit can be automatically started and put into operation for power supply; when a failure occurs, an audible and visual alarm The device will automatically alarm, and can remember the point of failure, and can automatically unload and shut down to ensure the safety of the unit. The control screen adopts full Chinese fluorescent display, soft touch switch, with good hand feeling, clear display and reliable action. At the same time, it can also design the control screen of two or more units automatically connected to the grid for the user. The Japanese Mitsubishi genset programmable controller PLC is used as the main control unit, and the Japanese variable pulse width and variable pulse interval software is used to design the speed control, so that the adjustment process is very advanced. Fast, accurate and stable, stable and reliable. Choose an automation system according to your specific requirements

5. Some companies have relatively high requirements for silence, such as schools, communities, etc., which require silent boxes.

6. The excitation method of diesel engine generator sets also requires special attention.

Second, how to choose a dg set

Certain diesel generator sets can be operated continuously for a certain period of time or often for a long time to serve as a common power supply for electric loads. Such generator sets are called common emergency backup generator sets. In order to supply electricity for local residents in towns, islands, forest farms, mines, oil fields and other areas or industrial and mining enterprises far away from the large power grid, diesel engine generators need to be installed. Such cummins backup generator should be carried out continuously, you could see the following C Series 94 kVA DG Set 50Hz details:

C Series 94 kVA DG Set 50Hz Specification
Generator Model
BP-C94Engine Model Cummins 6BT5.9-G1 (DCEC)
Standby Power 94kVA/75.2kW Prime Power 85kVA/68kW
Frequency 50Hz Rotational Speed 1500rpm

Engine Specification for C Series 94 kVA DG Set 50Hz

Governor Mechanical Weight 432KG
No. of Cylinders 6Aspiration Turbocharged
Displacement 5.9L Fuel System

BYC A Direct

 Injection

Hourly Fuel Consumption 

(100% Output Power)

21.7L

Minimum Required 

Oil Capacity

16.4L
Power Range

 86-92kW

Horse Power Range

115-123

Cummins 6BT series engines are all with features as compact size, low fuel consumption, low vibration, low noise, low maintenance, high parts commonality & long service life, providing powered diesel generator sets with great transient response, wide application, high economic efficiency & high reliability, and meeting the small or medium power (prime or standby) demand on residential use, small shops, small projects and other fields. 

Dimension: 2220mm*950mm*1530mm (Open type); 2980*980*1585mm (Silent type)

Weight: 1200 kg (Open type); 1690 kg (Silent type)

94 kVA Generator

However, after earthquakes, typhoons, wars and other natural disasters or human factors have damaged the municipal power grid and power genset outages, the standby units that have been set up should be started quickly and carried out uninterruptedly for a long time to ensure the use of electricity for these important projects. Continuous power genset supply of the load, this kind of standby generator set is also a common type of generator set.

The performance and quality of the selected diesel engine generator set must meet the requirements of relevant standards. Therefore, you must consider thoroughly when you have enough to buy, ask the diesel generator supplier clearly, and choose the dg set that suits you best.

Especially for 94kVA engine generator set. We will introduce you to the relevant knowledge of the electronically controlled unit pumps for dg set. The main brief is the assembly of the electronically controlled unit pumps for generator installation introduction:

1. The entire range of the sealing ring, the positioning hole, and the chamfer of the cylinder block that is in contact with the cylinder block of the dg genset unit pump is lubricated with lubricant;

2. The 2.4mm adjusting gasket of the diesel engine generator set is assembled on the center of the tappet;

3. Rotate the crankshaft so that the single pump tappet of the power genset is on the cam base circle, install the single pump, install the bolts, and the two bolts are pre-tightened synchronously with a torque of 5n.m, and then tightened at 30n.m;

4. The bolts and flanges of the cummins slient dg sets are marked with lead seals, and lead seal paint is applied 90 degrees around the bolts.

The above is the assembly steps of the generator set electronically controlled unit pump introduced by Bidirection Power Technology. Bidirection Power Technology Co., Ltd. is a professional genset manufacturer that can help you solve related questions about engine generator set.





FAQ
What are the types of generator sets?
There are many types of generator sets, and there are different types of generator sets according to different standards. 1. Divided by power source: diesel generator sets, gas generator sets, gasoline generator sets, wind generator sets, solar generator sets, hydroelectric generator sets, coal-fired generator sets, etc. 2. Electric energy mode: According to the converted electric energy mode, i...more
Get the latest price? We'll respond as soon as possible(within 12 hours)