C Series 550 kVA DG Set 50Hz
  • Bidirection Power
  • Cummins China
  • 30 - 45 days
  • 1000 sets

C Series 550 kVA DG Set 50Hz is powered by Cummins diesel engine KTA19-G4 which has many features as compact size, low fuel consumption, low vibration, low noise, low maintenance, high power output, high parts commonality & long service life, providing powered diesel gensets with great transient response, wide application, high economic efficiency & high reliability and meeting the medium or large power (prime or standby) demand on mining, hospitals, marines, military camps, factories, islands and other fields. Cummins serves customers with International Warranty Services (IWS). Selecting the location of the diesel engine generator room.

After we buy a dg set, we all need to configure the machine room for it. Everyone knows that, are there requirements for the generator set? Of course, the engine generator set itself has very high requirements for ventilation and heat dissipation. Therefore, we must consider comprehensively when selecting the location of the dg genset engine room. For the convenience of everyone, Bidirection Power Technology summarizes the location of the generator room for everyone. A few points to keep in mind.

Points for Attention in Choosing the Location of Diesel Generator Room

Diesel generator sets are required in many companies, so after we purchase diesel generator sets. How should the computer room to store it be constructed? What should I pay attention to?

Selection and layout of the engine diesel generator room location: Taking into account the air intake, exhaust, and smoke exhaust of the generator room, according to the requirements of the "Civil Building Electrical Design Code", the diesel generator room should be arranged on the first floor, but usually large public The first floor of civil buildings such as buildings and commercial buildings is a golden zone, and the first floor will bring certain noise to the surrounding environment. Therefore, according to the regulations, it can also be arranged in the basement when it is really difficult. Since the basement is not easy to enter and exit, it is naturally ventilated Poor conditions bring a series of unfavorable factors to the design of the computer room, so be careful when designing.

1. Pay attention to the following points when selecting the location of the computer room:

1. It should not be installed in a room with no external walls around, creating conditions for hot air ducts and smoke exhaust ducts to be discharged outside;

2. Try to avoid the main entrance, facade and other parts of the building to avoid the impact of exhaust air and smoke;

3. Pay attention to the impact of noise on the environment;

4. It should not be located directly below and adjacent to toilets, bathrooms or other places where water often accumulates;

5. It should be close to the substation of the building, which is convenient for wiring, reduces power loss, and is also convenient for management;

6. It should not be near a room with anti-flicker;

7. There is an oil storage room in the machine room;

8. Daylighting and lighting: The brightness of the machine room is not enough, which is not conducive for the staff to overhaul the unit, and seriously affects the maintenance of the equipment.

Second, the layout of the computer room

1. The engine diesel generator room should be separated from other parts by partition walls with fire resistance rating not less than 2.00 hours and floor slabs with 1.50 hours;

2. The machine room should have two entrances and exits. The size of one exit should meet the requirements of the handling unit. The door should be fireproof and soundproof, and it should be opened outward.

3. The walls and ceilings around the machine room are used as sound absorbers to absorb part of the sound energy and reduce the reverberation caused by sound wave reflection;

4. The layout of the equipment in the computer room should meet the requirements of the "Civil Building Electrical Design Code", and strive to be compact, safe, and easy to operate and maintain.

C Series 550 kVA DG Set 50Hz Specification
Generator Model
BP-C550Engine Model

Cummins KTA19-G4

 (CCEC)

Standby Power 550kVA/440kW Prime Power 500kVA/400kW
Frequency 50Hz Rotational Speed 1500rpm

Engine Specification for C Series 550 kVA DG Set 50Hz

Governor Electronic Weight 1855KG
No. of Cylinders 6Aspiration

Turbocharged and 

Aftercooled

Displacement 18.9L Fuel System

Direct Injection

 Cummins PT

Hourly Fuel 

Consumption 

(100% Output 

Power)

107L

Total System 

Oil Capacity

50L
Power Range

448-504kW

Horse Power Range

600-675

Dimension: 3380mm*1390mm*2050mm (Open type); 4570mm*1540mm*2200mm (Silent type)

Weight: 4166kg (Open type); 5370 kg (Silent type)

550 kVA Generator

If you buy the 550 kVA generator specification as the above, you could follow the point to select the location of the diesel engine generator room.

In summary, when we choose the location of the engine diesel generator room, we must comprehensively consider the air intake, exhaust, and smoke exhaust of the unit, because most of the time, once our generator set is moved into the genset engine room, it is rarely moved again. Therefore, in order to choose the most suitable home for the generator set, Bidirection Power Technology is here to remind everyone that you must be careful and considerate when selecting the location of the engine room, so that the generator set can exert the best performance.


FAQ
What are the types of generator sets?
There are many types of generator sets, and there are different types of generator sets according to different standards. 1. Divided by power source: diesel generator sets, gas generator sets, gasoline generator sets, wind generator sets, solar generator sets, hydroelectric generator sets, coal-fired generator sets, etc. 2. Electric energy mode: According to the converted electric energy mode, i...more