Get the latest price?

C Series 220 kVA DG Set 50Hz

  • C Series 220 kVA DG Set 50Hz Manufacturers, C Series 220 kVA DG Set 50Hz Factory, Supply C Series 220 kVA DG Set 50Hz
  • C Series 220 kVA DG Set 50Hz Manufacturers, C Series 220 kVA DG Set 50Hz Factory, Supply C Series 220 kVA DG Set 50Hz
  • C Series 220 kVA DG Set 50Hz Manufacturers, C Series 220 kVA DG Set 50Hz Factory, Supply C Series 220 kVA DG Set 50Hz
  • C Series 220 kVA DG Set 50Hz Manufacturers, C Series 220 kVA DG Set 50Hz Factory, Supply C Series 220 kVA DG Set 50Hz
  • C Series 220 kVA DG Set 50Hz Manufacturers, C Series 220 kVA DG Set 50Hz Factory, Supply C Series 220 kVA DG Set 50Hz
  • C Series 220 kVA DG Set 50Hz Manufacturers, C Series 220 kVA DG Set 50Hz Factory, Supply C Series 220 kVA DG Set 50Hz
C Series 220 kVA DG Set 50Hz
  • Bidirection Power
  • Cummins China
  • 30 - 45 days
  • 1000 sets

C Series 220 kVA DG Set 50Hz is powered by Cummins diesel engine 6CTAA8.3-G2 which has many features as compact size, low fuel consumption, low vibration, low noise, low maintenance, high parts commonality & long service life, providing powered diesel gensets with great transient response, wide application, high economic efficiency & high reliability and meeting the small or medium power (prime or standby) demand on residential use, small shops, small projects and other fields. Cummins serves customers with International Warranty Services (IWS).How to calculate the capacity of diesel engine generator set?

In modern general civil buildings, diesel engine generator sets are used for fire fighting loads in case of fire and provide backup power for important loads at ordinary times. The capacity of the diesel generator set should first meet the needs of stable calculation load, including the fire load and guaranteed load. So how should it be calculated? Bidirection Power Technology is here to introduce the calculation method of engine generator set C Series 220 kVA DG Set 50Hz  capacity.

As a fire-fighting load, dg genset are usually used as a backup power source for fire-fighting electrical equipment. Once the mains power goes out, the dg sets are interlocked and turned on immediately. In the event of a general power outage in a non-fire emergency state, loads such as life pumps, passenger elevators, hotel kitchen power, and star-rated guest room lighting (called guaranteed loads) also require backup power supply. If the diesel engine generator set is designed to only bear the fire-fighting load such as emergency lighting, and the guaranteed load cannot be taken into account, it will inevitably cause the set to be vacant and waste resources.

For this reason, when designing the low-voltage power distribution system, under the premise of meeting the needs of the fire protection load, it is possible to consider the power supply of the generator to the guaranteed load in the event of a power outage instead of a fire. One approach is to centrally connect the guaranteed load to the emergency bus section of the generator. In the event of a fire, the fire confirmation signal will guarantee the shunt trip of the main switch of the load (except for passenger elevators). In short, the fire load and guaranteed load should be calculated separately. When determining the capacity of a diesel generator set, the fire load requirements should be met first, and then the corresponding guaranteed load should be connected according to the requirements of the builder.

How to calculate the fire load correctly should arouse attention. The recommended calculation principle is to only consider a fire in one fire compartment (just like water fire fighting), that is, it is considered that the possibility of fire in two or more fire compartments at the same time is very low. Generally, the fire pump must be included as a fixed load, and how much load such as fire elevators and smoke exhaust fans are included depends on the size of the load put into service in a fire zone. The capacity of the commercial standby generator should be determined based on the fire-fighting load put into operation at the same time when a fire occurs in the most unfavorable fire compartment.

C Series 220 kVA DG Set 50Hz Specification
Generator Model
BP-C220Engine Model

Cummins

6CTAA8.3-G2 (DCEC)

Standby Power 220kVA/176kW Prime Power 200kVA/160kW
Frequency 50Hz Rotational Speed 1500rpm

Engine Specification for C Series 220 kVA DG Set 50Hz

Governor Electronic Weight 684KG
No. of Cylinders 6Aspiration

Turbocharged &

 Charge Air Cooled

Displacement 8.3L Fuel System

BYC P7100 Direct

 Injection

Hourly Fuel 

Consumption 

(100% Output 

Power)

45L

Minimum Required 

Oil Capacity

23.8L
Power Range

183-203kW

Horse Power Range

245-272

Cummins 6CTAA series engines are all with features as compact size, low fuel consumption, low vibration, low noise, low maintenance, high parts commonality & long service life, providing powered diesel generator sets with great transient response, wide application, high economic efficiency & high reliability, and meeting the small or medium power (prime or standby) demand on residential use, small shops, small projects and other fields. As a leading manufacturer of power equipment, Cummins serves customers with International Warranty Services (IWS) in approximately 190 countries and territories through a network of more than 600 company-owned and independent distributor locations and approximately 7,400 dealer locations.

Alternator: Stamford, Leroy Somer, Marathon, Mecc Alte, Engga, etc. With great excitation, enable genset to bear high power transient load. Ratings: Power Factor 0.8, 3 Phase 4 Wire, H insulation & IP23;

Control System: ComAp, Deepsea, Smartgen, etc. To control gensets intelligently and support genset in stable operation;

Shortcut Protection: standard three phase Delixi MCCB. Schneider & ABB for options

Radiator: standard 50℃ radiator, closed water cooled system, to support rated power output under strict temperature environment

Anti-vibration Shock Absorbers: with built-in integrated anti-vibration system, easy for transportation & installation

Fuel Tank: open type without fuel tank and silent type with built-in fuel tank (8-10 operating hours capacity);

Start Motor: DC 24V start motor;

Battery & charger: with 2 maintenance free batteries (120AH) and one DC battery charger (24V), to support genset with reliable starting power supply;

Dimension: 2540mm*950mm*1750mm (Open type); 3560*1220*1810mm (Silent type)

Weight: 1810 kg (Open type); 2590 kg (Silent type)

220 kVA Generator

In addition to satisfying the above-mentioned stable calculation load requirements, the capacity of the diesel generator set must also be checked for the voltage drop when the motor is started, that is, when any motor is started, the allowable voltage drop at its terminals should be within the specified range. I hope the above explanation can help everyone better understand diesel engine generator sets.

If 220kVA is slient dg set type, then we bidirection will guide you to pick up the best types.

Before starting the super silent diesel generator set, check and turn off the control switch power/emergency standby shutdown switch. Do not open the radiator cover when the coolant or heat of the silent generator set is still working. Do not add a large amount of coolant to the thermal cooling system, otherwise it will cause serious damage to the 10kva silent generator set. Check the oil and coolant level of the silent generator set. Fill it when insufficient. When injecting fuel into the mini silent generator set, do not smoke or use an open flame to check whether the fuel is clean.

Check the fuel oil level of the silent generator set, add it if necessary, check the tightness of the silent dg diesel generator set cooling fan and feeding belt, and tighten if there is any looseness. Check whether all the hose joints of the silent generator set are loose, broken or worn. If so, tighten or replace them. Check the battery level of the silent dg generator set. Add distilled water if necessary. If the genset portable silent battery is new and has never been charged, please add pre-matched battery fluid.

Check the silent genset for home control panel and generator for large amounts of dust and dirt, which may cause electric shock or cooling problems in the silent diesel generator output. Check the mute generator set air filter clogging indicator, if clogged, replace the filter. Clean up the site around the silent generator set, remove unsafe items, avoid affecting the operation of the silent generator set or causing danger, and ensure that the cooling and ventilation network is not blocked.

Observe and check the fuel system, cooling system, and lubricating oil seal of the silent generator set. When the exhaust system of the genset super silent standby generator set has a drain valve, the condensate is regularly discharged. Ensure that the output circuit switch of the alternator is in the (closed) state (handle down), check the lubricating oil level of the silent generator set, add lubricating oil if necessary, because the silent generator set without an automatic control system can be automatically without warning Start, close the silent dg silent generator control panel before checking.

cummins diesel generator


FAQ
What are the types of generator sets?
There are many types of generator sets, and there are different types of generator sets according to different standards. 1. Divided by power source: diesel generator sets, gas generator sets, gasoline generator sets, wind generator sets, solar generator sets, hydroelectric generator sets, coal-fired generator sets, etc. 2. Electric energy mode: According to the converted electric energy mode, i...more
Get the latest price? We'll respond as soon as possible(within 12 hours)
close left right