Get the latest price?

C Series 200 kVA DG Set 50Hz

  • C Series 200 kVA DG Set 50Hz Manufacturers, C Series 200 kVA DG Set 50Hz Factory, Supply C Series 200 kVA DG Set 50Hz
  • C Series 200 kVA DG Set 50Hz Manufacturers, C Series 200 kVA DG Set 50Hz Factory, Supply C Series 200 kVA DG Set 50Hz
  • C Series 200 kVA DG Set 50Hz Manufacturers, C Series 200 kVA DG Set 50Hz Factory, Supply C Series 200 kVA DG Set 50Hz
  • C Series 200 kVA DG Set 50Hz Manufacturers, C Series 200 kVA DG Set 50Hz Factory, Supply C Series 200 kVA DG Set 50Hz
C Series 200 kVA DG Set 50Hz
  • Bidirection Power
  • Cummins China
  • 30 - 45 days
  • 1000 sets

C Series 200 kVA DG Set 50Hz is powered by Cummins diesel engine 6CTA8.3-G2 which has many features as compact size, low fuel consumption, low vibration, low noise, low maintenance, high parts commonality & long service life, providing powered diesel gensets with great transient response, wide application, high economic efficiency & high reliability and meeting the small or medium power (prime or standby) demand on residential use, small shops, small projects and other fields. Cummins serves customers with International Warranty Services (IWS).What are the most common mistakes when using Cummins generator set?

Nowadays, Cummins house generator sets on the market are more and more favored by users. Therefore, how to properly use, maintain the generator sets is very important. In this article, Bidirection Power Technologys power generation equipment will be explained in detail based on the misunderstandings in the use of the diesel engine of the unit, to avoid failures in time, better maintain and extend the use time.

1. The more oil in the oil pan, the better. In order to prevent the Cummins generator set from burning tiles, some people think that the more oil in the oil pan, the more safe it is, and the oil often exceeds the specified height of the oil level. This approach is wrong. Generally, diesel engines are equipped with an oil dipstick that can check the oil level of the oil pan. There are two engraved lines on the dipstick, and the oil should be filled between the upper and lower engraved lines. If it is lower than the lower score line, the normal lubrication of the relative moving parts cannot be guaranteed, which will aggravate the wear of the parts, and even cause the burning of the shaft. If the oil level exceeds the upper engraved line, it is easy to cause burning and draining of oil, resulting in cementation of the piston ring, reduced sealing, blue smoke from the exhaust, large oil consumption, carbon deposits, and accelerated mechanical wear.

2. The lower the throttle, the more "fuel-efficient". Whether a Cummins dg generator set saves fuel during operation does not depend on the amount of fuel consumed per unit time, but on how much effective work can be produced by consuming a certain amount of fuel. Therefore, fuel consumption is usually used as a measure of fuel economy, that is, an indicator of economic performance. In the case of a certain diesel engine load, the circulating fuel supply is basically unchanged when the throttle position is changed. As a result, it only changed the speed range of the governor and the speed of the Cummins generator set. However, within the operating speed range of the diesel engine generator set, the change of speed has little effect on fuel consumption. It can be seen from this that when Cummins marine generator sets work under a certain load, it is not that the lower the throttle, the more fuel-efficient. This is because when the throttle is reduced, the speed of the diesel engine will decrease, and the working efficiency will decrease. Therefore, as long as the operating speed allows, it is more advantageous to use a larger throttle to operate.

3.The tighter the cylinder head bolt, the better When installing the cylinder head of a Cummins diesel generator set, some people think that the tighter the cylinder head bolts, the better the sealing. Others said: "I would rather unscrew it than loose it". This view is wrong. Because the result of this will inevitably cause deformation and bulge around the cylinder bolt hole, resulting in uneven joint surface, cylinder head bolt is also stretched or slipped due to excessive stress, so that the pressing force of the joint surface is reduced and Uneven. It can be seen that excessive tightening of cylinder head bolts is harmful. The correct way is to tighten them to the specified torque in a certain order (2, 3 times).

4.The lower the cooling water temperature, the better. Some people think that the lower the temperature of the diesel engine cooling water of Cummins diesel standby generator sets, the better, so the diesel engine releases part of the hot water from time to time during operation, and then adds cold water. In fact, low water temperature is also harmful:

a. The thermal efficiency of dongfong Cummins generator set is reduced. Due to the excessive cooling of the body temperature, the ignition of the diesel engine is delayed, the combustion is poor, the speed is unstable, the power is reduced, the fuel consumption is increased, and carbon deposits are easy.

b. It is easy to cause the burning gas to condense into water and form acidic compounds with the sulfur in diesel oil to corrode the parts. So as to accelerate the damage of the mechanical parts. The normal cooling water temperature should be 80%, and the evaporative heat dissipation can be higher.

5. The tighter the installation of the transmission belt, the better. If the transmission belt (or V-belt) is installed too loosely, the belt will inevitably slip, resulting in lower working efficiency. But the belt installation is not as tight as possible. Because the transmission belt is too tight, firstly, it will increase the radial pressure of the main shafts of the connected two machines, which is easy to cause deformation of the two shafts or early damage to the bearings; secondly, the mechanical load of the transmission force is heavier, and it is easy to malfunction; thirdly, it will increase the transmission belt itself Tensile force shortens its service life.

C Series 200 kVA DG Set 50Hz Specification
Generator Model
BP-C200Engine Model Cummins 6CTA8.3-G2(DCEC)
Standby Power 200kVA/160kW Prime Power 180kVA/144kW
Frequency 50Hz Rotational Speed 1500rpm

Engine Specification for C Series 200 kVA DG Set 50Hz

Governor Electronic Weight 637KG
No. of Cylinders 6Aspiration

Turbocharged &

 Aftercooled

Displacement 8.3L Fuel System

BYC PB Direct

 Injection

Hourly Fuel 

Consumption 

(100% Output 

Power)

44L

Minimum Required 

Oil Capacity

27.6L
Power Range

 163-180kW

Horse Power Range

218-241

Dimension: 2420mm*950mm*1530mm (Open type); 3280*1080*1765mm (Silent type)

Weight: 1690 kg (Open type); 2260 kg (Silent type)

200 kVA Generator

If you are buying a generator 200 kVA, you could check the specification if you have the misunderstanding.

The above are some misunderstandings that are easy to appear when using Cummins home backup generator sets introduced by Bidirection Power Technology for everyone. When using Cummins generator sets 200 kVA generator, you must pay more attention to avoid some misunderstandings that may cause unit damage. If you dont understand, You should also consult a professional Cummins back up generator set manufacturer before proceeding.


FAQ
What are the types of generator sets?
There are many types of generator sets, and there are different types of generator sets according to different standards. 1. Divided by power source: diesel generator sets, gas generator sets, gasoline generator sets, wind generator sets, solar generator sets, hydroelectric generator sets, coal-fired generator sets, etc. 2. Electric energy mode: According to the converted electric energy mode, i...more
Get the latest price? We'll respond as soon as possible(within 12 hours)
close left right