Get the latest price?

C Series 344 kVA DG Set 50Hz

  • C Series 344 kVA DG Set 50Hz Manufacturers, C Series 344 kVA DG Set 50Hz Factory, Supply C Series 344 kVA DG Set 50Hz
  • C Series 344 kVA DG Set 50Hz Manufacturers, C Series 344 kVA DG Set 50Hz Factory, Supply C Series 344 kVA DG Set 50Hz
  • C Series 344 kVA DG Set 50Hz Manufacturers, C Series 344 kVA DG Set 50Hz Factory, Supply C Series 344 kVA DG Set 50Hz
  • C Series 344 kVA DG Set 50Hz Manufacturers, C Series 344 kVA DG Set 50Hz Factory, Supply C Series 344 kVA DG Set 50Hz
  • C Series 344 kVA DG Set 50Hz Manufacturers, C Series 344 kVA DG Set 50Hz Factory, Supply C Series 344 kVA DG Set 50Hz
C Series 344 kVA DG Set 50Hz
  • Bidirection Power
  • Cummins China
  • 30 - 45 days
  • 1000 sets

C Series 344 kVA DG Set 50Hz is powered by Cummins diesel engine 6LTAA9.5-G1 which has many features as compact size, low fuel consumption, low vibration, low noise, low maintenance, high parts commonality & long service life, providing powered diesel gensets with great transient response, wide application, high economic efficiency & high reliability and meeting the small or medium power (prime or standby) demand on residential use, small shops, small projects and other fields. Cummins serves customers with International Warranty Services (IWS).Precautions for purchasing diesel engine generator sets for mines.

China is a big energy country. There are many mines in some areas in northern my country. Because of the remoteness, long power supply and transmission lines, the location of underground operators, the need to monitor gas and air supply, etc., the mines must be equipped with emergency backup generators. Some special areas need to use engine generator sets for long-term main power genset due to the inaccessibility of the main line. Therefore, mine dg sets have higher power requirements than conventional places. So we need to pay attention when purchasing mine dg genset. What are the problems?

Knowing the electrical equipment of your own mine is the first step. What you need to know is the type of electrical equipment and the power of the main motor, starting method, starting law and other factors. What needs to be specifically explained here is that the equipment of the mine is generally a single motor. The power of the generator is very large, so it is necessary to choose a more excellent starting method, otherwise the investment budget for choosing a dg set will be doubled.

On the other hand, large motors used in mines have a common feature, that is, the problem of large starting load but small load after operation. If the calculation is not good or the starting method selected is not good, it will waste a lot of manpower, material resources and financial resources. At present, the starting methods of motors are roughly as follows: direct start/Y-step-down start/self-coupling step-down start/soft start/frequency conversion start, etc. Most mines use large-capacity motors, the first two are basically impossible, so You can make comprehensive choices in the latter three based on your own investment budget, communicate with equipment manufacturers and generator sets manufacturers, and select the best and appropriate plan. After selecting the starting mode, calculate the starting current (during the worst working condition) and running current of all equipment, and finally calculate how much power genset needs to be configured.

In mines, everyone knows that the use environment is very harsh, and even some places are in high altitude areas. The power carrying capacity of dg set is the same as human beings. The power carrying capacity decreases with the increase in altitude, so special attention must be paid to this factor. Take it into consideration, otherwise it will cause the disadvantages of the purchased power and the actual operating power.

Manufacturers of engine generator sets specializing in mines will have some special configurations, such as heavy-duty filters for wind and sand prevention, low-temperature starting devices, early warning devices for regular maintenance of the units, and advanced crankcase pressure alarm devices. The device is undoubtedly the greatest protector of the generator set. Most of the mines dg genset are operated in parallel. The signs of major faults in the dg set cannot be observed with sound or naked eyes (such as abnormal noise, jitter, minor three leaks, etc.). The alarm device can effectively monitor the crankcase pressure, and can greatly avoid the occurrence of some major engine failures (such as the fatal cylinder pull and pull phenomenon for the generator set).

Most of the mine's generator sets are far away from the main urban area, so the technical level of the generator set operators must be high. The improvement of this type of technology can be achieved through cooperation with some manufacturers with large-scale training and technical support. The unit is an important means of production for the mine, and it is natural to call it the "pioneer army". Therefore, it is particularly important to deploy high-level technicians!

For the mine generator set used by the main force, it is necessary to reserve one more set for long-term backup. This seems to have a large investment in the short term, but as long as it is equipment, when there will eventually be a failure, then one more standby dg set must be very necessary in the long run!

If you buy 344 kVA dg set for mine industry standby and prime power application, you could check the following specification.

C Series 344 kVA DG Set 50Hz Specification
Generator Model
BP-C344Engine Model

Cummins

6LTAA9.5-G1 (DCEC)

Standby Power 344kVA/275kW Prime Power 313kVA/250kW
Frequency 50Hz Rotational Speed 1500rpm

Engine Specification for C Series 344 kVA DG Set 50Hz 

Governor Electronic Weight 822KG
No. of Cylinders 6Aspiration

Turbocharged &

 Charge Air Cooled

Displacement 9.5L Fuel System

BYC P7100

 Direct Injection

Hourly Fuel 

Consumption 

(100% Output 

Power)

70L

Minimum Required Oil Capacity

28.1L
Power Range

 273-300kW

Horse Power Range

366-402

Cummins 6LTAA series engines are all with features as compact size, low fuel consumption, low vibration, low noise, low maintenance, high parts commonality & long service life, providing powered diesel generator sets with great transient response, wide application, high economic efficiency & high reliability, and meeting the small or medium power (prime or standby) demand on residential use, small shops, small projects and other fields. 

Dimension: 2580mm*1020mm*1670mm (Open type); 3560*1220*1815mm (Silent type)

Weight: 2220 kg (Open type); 3000 kg (Silent type)

344 kVA Generator

The last point is that the mine dg set needs to routinely purchase and inventory the daily wearing parts and easy-to-fault parts, so that spare parts can be provided for emergency standby power when a failure occurs.

FAQ
What are the types of generator sets?
There are many types of generator sets, and there are different types of generator sets according to different standards. 1. Divided by power source: diesel generator sets, gas generator sets, gasoline generator sets, wind generator sets, solar generator sets, hydroelectric generator sets, coal-fired generator sets, etc. 2. Electric energy mode: According to the converted electric energy mode, i...more
Get the latest price? We'll respond as soon as possible(within 12 hours)
close left right