  • Bidirection Power
  • Cummins China
  • 30 - 45 days
  • 1000 sets

C Series 66 kVA DG Set 50Hz is powered by Cummins diesel engine 4BTA3.9-G2 which has many features as compact size, low fuel consumption, low vibration, low noise, low maintenance, high parts commonality & long service life, providing powered diesel gensets with great transient response, wide application, high economic efficiency & high reliability and meeting the small or medium power (prime or standby) demand on residential use, small shops, small projects and other fields. Cummins serves customers with International Warranty Services (IWS).What maintenance measures should be taken for silent dg engine generator sets in application?

What maintenance measures should be taken for silent dg engine generator sets in use?

As slient dg is popular nowadays, we take C Series 66 kVA DG Set 50Hz slient type to explain more details. Generally, silent dg generator sets are equipped with air filters, and the intake noise of silent diesel engine generator sets can be greatly attenuated and become a secondary sound source. When other sound sources are further controlled, the intake noise of the silent generator set may become the main sound source. At this time, it is necessary to consider the use of a good-performance intake muffler. Generally, the intake muffler of a silent dg set should be combined with an air filter. The integrated design can not only meet the requirements of air intake and filtration, but also can effectively control the intake noise of the silent engine generator set.

Usually the design of muffler is mainly based on experience, and some design calculation procedures are carried out under some ideal assumptions, and the actual influence of these assumptions is to ignore the existence of airflow, and it is the existence of high pressure, high temperature, high-speed pulsating airflow. The airflow in this state will affect the sound field distribution, sound velocity, and sound propagation law inside the muffler of the silent diesel engine generator set, especially the airflow speed of the mini silent generator set.

When the structural parameters of the muffler are improperly selected, or the structure is unreasonable, or the processing technology has problems, it will cause the reduction of the muffler's silencing performance. At the same time, too high air velocity will increase the pressure loss of the muffler and cause the reduction of the silencing performance. The control of engine surface radiated noise is subject to various restrictions on engine performance, which is very difficult from a technical point of view, and the amount of noise reduction is limited. Slient dg  C Series 66 kVA DG Set 50Hz configuration as following:

C Series 66 kVA DG Set 50Hz Specification
Generator Model
BP-C66Engine Model Cummins 4BTA3.9-G2 (DCEC)
Standby Power 66kVA/52.8kW Prime Power 60kVA/48kW
Frequency 50Hz Rotational Speed 1500rpm

Engine Specification for C Series 66 kVA DG Set 50Hz

Governor Electronic Weight 350KG
No. of Cylinders 4Aspiration

Turbocharged &

 Aftercooled

Displacement 3.9L Fuel System BYC A Direct Injection

Hourly Fuel 

Consumption 

(100% Output 

Power)

12.9L

Minimum Required 

Oil Capacity

10.9L
Power Range

50-55kW

Horse Power Range

67-74

Cummins 4BTA series engines are all with features as compact size, low fuel consumption, low vibration, low noise, low maintenance, high parts commonality & long service life, providing powered diesel generator sets with great transient response, wide application, high economic efficiency & high reliability, and meeting the small or medium power (prime or standby) demand on residential use, small shops, small projects and other fields. As a leading manufacturer of power equipment, Cummins serves customers with International Warranty Services (IWS) in approximately 190 countries and territories through a network of more than 600 company-owned and independent distributor locations and approximately 7,400 dealer locations.

Battery & charger: with 2 maintenance free batteries (80AH) and one DC battery charger (24V), to support genset with reliable starting power supply;

Dimension: 1870mm*950mm*1500mm (Open type); 2240*980*1585mm (Silent type)

Weight: 950 kg (Open type); 1210 kg (Silent type)

66 kVA Generator

The method of using the silent dg set correctly is introduced as follows, there are three main types:

1. First, pay attention to the manual operation of the silent dg set:

a. Check whether the fuel, oil, and cooling water are appropriate before manual startup. Insufficiencies should be supplemented in time. The unit should have no oil or water leakage. For reference only (Answer from bidirection power technology)

b. The automatic control button of the automatic controller should be set to the middle position.

c. Turn on the key of the starting circuit and continue to turn the key to the right to start the diesel engine. After the start is successful, set the key back to the charging position.

d. After stopping, the key should be dialed back to the middle position in time. )

2. Silent dg genset set automatic operation:

a. Under normal mains power conditions, move the automatic control button of the automatic controller up to the "automatic" position. It is forbidden to start the diesel engine manually. When the mains power fails, the diesel generator set can automatically start and automatically supply power to the grid through the ATS switch.

b. After the unit automatically starts running, turn the key switch to the charging position in time.

c. The unit can automatically shut down after the utility power comes in. After stopping the machine, turn the key switch to the middle position to prevent the battery from failing and affecting the next use.

3. maintenance, maintenance:

a. The new machine needs to change the oil, clean the diesel filter, and the air filter after 60 hours of operation.

b. The battery electrolyte should be checked frequently, and should be refilled in time when it is insufficient.

c. Check the tightness of the belt frequently, adjust the tension mechanism, and maintain the tension.

d. The water heating and oil heating switches should be turned on in the cold season to keep the unit at a certain temperature to ensure that the unit can be used normally.

Practice has shown that taking structural measures can reduce the surface radiation noise of the silent dg set to a certain extent, thereby reducing the noise of the whole machine. The basic control measures are to increase the structural stiffness and damping, so that the surface response of the silent generator set is reduced under the same excitation force. At the same time, reducing the surface area of radiated noise of silent dg sets is also an effective measure to control the radiated noise of silent generator sets.



FAQ
What are the types of generator sets?
There are many types of generator sets, and there are different types of generator sets according to different standards. 1. Divided by power source: diesel generator sets, gas generator sets, gasoline generator sets, wind generator sets, solar generator sets, hydroelectric generator sets, coal-fired generator sets, etc. 2. Electric energy mode: According to the converted electric energy mode, i...more
Get the latest price? We'll respond as soon as possible(within 12 hours)
close left right