Get the latest price?

C Series 625 kVA DG Set 50Hz

  • C Series 625 kVA DG Set 50Hz Manufacturers, C Series 625 kVA DG Set 50Hz Factory, Supply C Series 625 kVA DG Set 50Hz
  • C Series 625 kVA DG Set 50Hz Manufacturers, C Series 625 kVA DG Set 50Hz Factory, Supply C Series 625 kVA DG Set 50Hz
  • C Series 625 kVA DG Set 50Hz Manufacturers, C Series 625 kVA DG Set 50Hz Factory, Supply C Series 625 kVA DG Set 50Hz
  • C Series 625 kVA DG Set 50Hz Manufacturers, C Series 625 kVA DG Set 50Hz Factory, Supply C Series 625 kVA DG Set 50Hz
  • C Series 625 kVA DG Set 50Hz Manufacturers, C Series 625 kVA DG Set 50Hz Factory, Supply C Series 625 kVA DG Set 50Hz
C Series 625 kVA DG Set 50Hz
  • Bidirection Power
  • Cummins China
  • 30 - 45 days
  • 1000 sets

C Series 625 kVA DG Set 50Hz is powered by Cummins diesel engine KTAA19-G6 which has many features as compact size, low fuel consumption, low vibration, low noise, low maintenance, high power output, high parts commonality & long service life, providing powered diesel gensets with great transient response, wide application, high economic efficiency & high reliability and meeting the medium or large power (prime or standby) demand on mining, hospitals, marines, military camps, factories, islands and other fields. Cummins serves customers with International Warranty Services (IWS).How to adjust the fuel supply of Cummins generator set for 625 kVA generator.

If the oil supply of each cylinder of Cummins silent generator set as per 625 kVA generator is uneven (for example, some cylinders have too much oil supply, and some cylinders have too small oil supply), it will directly affect the stability of the engine. The fuel injection pump can be removed to check and adjust on the test bench. However, if there is no test bench and the uneven oil supply must be checked, the oil supply of the suspected cylinder can also be roughly checked. Therefore, it is necessary to adjust the fuel supply of Cummins generator set at this time. How should it be adjusted? We will teach you the following methods:

1. Prepare two glass measuring cylinders for later use. If you cannot find the measuring cylinder for a while, you can also use two identical vials instead.

2. Remove the high-pressure oil pipe joint that connects the fuel injector to the cylinder with too much fuel supply (or too small).

3. Remove the high-pressure pipe joint that connects the fuel injector to the first cylinder with normal fuel supply.

4. Insert the ends of the two oil pipes into two measuring cylinders (or vials) respectively.

5. Use the genset engine starter to rotate the power engine to pump oil from the fuel injection pump.

6. When there is a certain amount of dg in the graduated cylinder (or vial), place the graduated cylinder on the water platform and compare the amount of oil to determine whether the fuel supply is too large or too small. If a vial is used instead, it can be weighed and compared. The relative position of the fork (or gear ring) on the fuel injection pump oil volume adjustment rod (that is, the gear rod) can be changed for adjustment. The P_ type pump can be adjusted by rotating the flange sleeve.

The above is the method to check and adjust the fuel supply of Cummins generator set by Bidirection Power Technology. When using Cummins generator set, you must pay more attention to whether the fuel supply of each cylinder is even and adjust in time to ensure Cummins power generation Normal use of the unit.

C Series 625 kVA DG Set 50Hz Specification
Generator Model
BP-C625Engine Model Cummins KTAA19-G6(CCEC)
Standby Power 625kVA/500kW Prime Power 563kVA/450kW
Frequency 50Hz Rotational Speed 1500rpm

Engine Specification for C Series 625 kVA DG Set 50Hz 

Governor Electronic Weight 1905KG
No. of Cylinders 6Aspiration Turbocharged and Air to Air Aftercooled
Displacement 18.9L Fuel System

Direct Injection

 Cummins PT

Hourly Fuel 

Consumption 

(100% Output 

Power)

141.5L

Total System Oil 

Capacity

50L
Power Range

 570kW

Horse Power Range

764

625 kVA Generator

Cummins KTAA19 series engines are all with features as compact size, low fuel consumption, low vibration, low noise, low maintenance, high power output, high parts commonality & long service life, providing powered diesel gensets with great transient response, wide application, high economic efficiency & high reliability and meeting the medium or large power (prime or standby) demand on mining, hospitals, marines, military camps, factories, islands and other fields. 

Dimension: 3670mm*1680mm*2190mm (Open type); 5000mm*1900mm*2400mm (Silent type)

Weight: 4650 kg (Open type); 7250 kg (Silent type)

The above specification is the details for 625 kVA generator to support you to adjust the fuel supply of Cummins generator set for 625 kVA generator.


FAQ
What are the types of generator sets?
There are many types of generator sets, and there are different types of generator sets according to different standards. 1. Divided by power source: diesel generator sets, gas generator sets, gasoline generator sets, wind generator sets, solar generator sets, hydroelectric generator sets, coal-fired generator sets, etc. 2. Electric energy mode: According to the converted electric energy mode, i...more
Get the latest price? We'll respond as soon as possible(within 12 hours)