C Series 880 kVA DG Set 50Hz is powered by Cummins diesel engine KTA38-G2B which has many features as compact size, low fuel consumption, low vibration, low noise, low maintenance, high power output, high parts commonality & long service life, providing powered diesel gensets with great transient response, wide application, high economic efficiency & high reliability and meeting the medium or large power (prime or standby) demand on mining, hospitals, marines, military camps, factories, islands and other fields. Cummins serves customers with International Warranty Services (IWS).Overview of the application and maintenance of Cummins marine generator sets.
Generator sets are widely used in the marine industry, and Cummins marine generator sets can be said to be the most widely used generator marine sets. So what maintenance is generally required for marine Cummins generator sets? Is there any difference from the unit maintenance we usually use? The following interoperable power will briefly talk about the use and maintenance of marine Cummins generator sets:
1. General maintenance
In order to ensure the normal operation of the marine Cummins marine generator set, there should be no water, oil and dirt accumulation around it, and no corrosive gas, so as not to damage the generator winding insulation.
While preventing moisture and dust, pay attention not to affect the normal ventilation and cooling of marine Cummins generator sets. Always clean the dust and dirt in the vents and keep them unobstructed. The temperature of the cooling air should not be too low to avoid condensation on the windings and other conductive parts.
For marine Cummins dg set that stop running for a short time for some reason, the slip ring does not need to be wrapped for protection, but insulating cardboard, paraffin paper or asphalt paper should be placed between the brush and the slip ring to prevent the brush from being trapped. Spots are formed on the surface of the electric ring.
If the machined surface of the Cummins marine dc generator set is rusted due to oil or paint peeling off, it should be derusted in time and painted with anti-rust paint.
2. Precautions for disassembly and assembly
The disassembly and assembly method of marine Cummins generator set is roughly the same as that of asynchronous dg genset motor. However, due to the heavy weight of the generator, care should be taken not to damage it during disassembly and assembly. When removing the end cover, be careful not to damage the genset stater coil protruding from the surface of the base; when removing the rotor, put cardboard between the genset stater and rotor of the genset motor to prevent damage to the iron core and windings. When tying the rotor with steel cables, The steel cable shall not touch the rotor journal, phoenix fan, collector slip and lead wire that changes hands. The place where the rope is tied must be padded with wood or rubber;
3. Drying of generator
The newly installed marine Cummins genset engine set should generally be dried before operation. If the insulation resistance meets the requirements, drying is not required, but the load within 24 hours of the start of operation should preferably not exceed 50% of the rated capacity.
880 kVA dg set could be used in marine industry according to the following specification:
C Series 880 kVA DG Set 50Hz Specification | |||
Generator Model | BP-C880 | Engine Model | Cummins KTA38-G2B(CCEC) |
Standby Power | 880kVA/704kW | Prime Power | 800kVA/640kW |
Frequency | 50Hz | Rotational Speed | 1500rpm |
Engine Specification for C Series 880 kVA DG Set 50Hz | |||
Governor | Electronic | Weight | 3719KG |
No. of Cylinders | 12 | Aspiration | Turbocharged and Air to Air Aftercooled |
Displacement | 38L | Fuel System | Direct Injection Cummins PT |
Hourly Fuel Consumption (100% Output Power) | 142L | Total System Oil Capacity | 135.1L |
Power Range | 711-790kW | Horse Power Range | 953-1058 |
Cummins KTA38 series engines are all with features as compact size, low fuel consumption, low vibration, low noise, low maintenance, high power output, high parts commonality & long service life, providing powered diesel gensets with great transient response, wide application, high economic efficiency & high reliability and meeting the medium or large power (prime or standby) demand on mining, hospitals, marines, military camps, factories, islands and other fields.
Dimension: 4410mm*1720mm*2170mm (Open type); 6050mm*2430mm*2580mm (20FT Containerized type)
Weight: 7190 kg (Open type); 10100 kg (20FT Containerized type)
The above is the application and maintenance of marine Cummins dg set introduced by Bidirection Power. When you use marine Cummins generator set, you must pay more attention to maintenance to extend its service life.
In the future development direction of engine generators set, intelligence is the ultimate goal
The diesel engine generator set is the earliest energy equipment of mankind. The first engine generator set invented by Michael Faraday. Today, the new concept of intelligent automatic dg set based on Internet technology has experienced more than 180 years of development history. Made a huge contribution. However, with the development of power grid facilities more and more perfect, the status of generators is also undergoing changes in varying degrees. Genset power have been transformed from primary power generation equipment to industrial-grade standby power sources, and then to today's emergency standby power sources. Where to go for future generators is worthy of our industry's thinking and forge ahead.
With the development of Internet technology at any time, various industries have achieved innovative development, and dg gensets are no exception. According to some special needs of different industries, generator management has put forward higher requirements, especially in the field of communication, due to the distribution of computer rooms It is located in a mountain or remote area, and it is very difficult to manage and maintain. The traditional manual management model is too outdated to meet the needs. Therefore, the communication field first put forward the requirement that generators need to achieve centralized remote monitoring and management.We Bidirection Power seized the opportunity and took the lead in research and development to achieve remote monitoring and management of diesel generators, which realized unattended, centralized management and generators. Operating status, remote start and stop, automatic generator inspection, automatic fault alarm, fault record data analysis, statistical reports, power generation management, fuel management, etc. In terms of management, it has also completely changed the traditional management mode of engine generators, which can be easily managed through PC, mobile phone text messages, and APP, which saves time and effort, and operates with high efficiency. The same Internet-based generator remote monitoring system also brings more opportunities and business opportunities to generator manufacturers. Creative ideas and ideas that may not be realized by genset manufacturer before can be realized through Internet technology, such as: increasing the selling point of the unit and improving generator repair service capability and competitiveness, etc. Internet technology has undoubtedly become an important direction for the development of generators, and has given wings to the intelligentization of generators.
There are many types of generator sets, and there are different types of generator sets according to different standards. 1. Divided by power source: diesel generator sets, gas generator sets, gasoline generator sets, wind generator sets, solar generator sets, hydroelectric generator sets, coal-fired generator sets, etc. 2. Electric energy mode: According to the converted electric energy mode, i...more