C Series 1000 kVA DG Set 50Hz

- Bidirection Power
- Cummins China
- 30 - 45 days
- 1000 sets
C Series 1000 kVA DG Set 50Hz is powered by Cummins diesel engine KTA38-G2A which has many features as compact size, low fuel consumption, low vibration, low noise, low maintenance, high power output, high parts commonality & long service life, providing powered diesel gensets with great transient response, wide application, high economic efficiency & high reliability and meeting the medium or large power (prime or standby) demand on mining, hospitals, marines, military camps, factories, islands and other fields. Cummins serves customers with International Warranty Services (IWS).Two problems when diesel engine generator sets are running
There are the following two problems when diesel engine generator sets C Series 1000 kVA DG Set 50Hz are running:
(1) Potential safety hazards: First, the unit must open doors and windows to dissipate heat during operation. Due to external factors, it is difficult to ensure the safe operation of the equipment; second, noise pollution. The measured noise value of 15m outside the machine room is 110dbA. The unit runs continuously for a long time, which is harmful to employees. Physical and mental health interferes with normal production operations.
(2) High maintenance cost: First, the unit is in a semi-exposed state and is eroded by rain, snow, wind and sand, and the maintenance frequency must be increased to ensure normal operation; second, the dg genset room has poor corrosion resistance and needs to be repaired every year.
2 Development process
(1) Development requirements
The development of DQ10 diesel engine generator set muffler device should achieve the following points:Meet the requirements of the HSE operation system of the oil test and production company;According to the "Urban Area Environmental Noise Standard (GB3096-93)", the environmental noise in the accommodation area meets the Class I standard; the surrounding noise of the power genset room meets the Class II standard;Pay equal attention to strength and performance to ensure safe and reliable operation of the unit;People-oriented, perfect harmony between equipment and environment.Diesel engine generator set produce noise when they are running, so the muffler came into being. The following introduces the quality standards of generator set mufflers.
1. The muffler frequency characteristics of the muffler. The anti-spray-resistance muffler has a superior effect on various frequency noises.
2. The applicable wind speed of the muffler is generally 6-8ms, and the highest should not exceed 12ms. At the same time, pay attention to the pressure loss of the muffler.
3. The noise reduction performance of the muffler; (the amount of noise reduction and frequency spectrum characteristics)
4. Aerodynamic performance of the muffler; (pressure loss, etc.)
5. The structural performance of the muffler. (Size, price, life, etc.)
6. Pay attention to the cross-sectional area of the clear passage of the muffler. When the air duct and the muffler are connected, it needs to be enlarged if necessary (when the wind speed is limited).
7. The installation of muffler equipment such as muffler must have an independent load-bearing boom or base; it must be connected with the sound source equipment through a soft joint.
8. When two muffler elbows are used in series, the connection distance between the two elbows should be greater than 2.5 times the diagonal length of the elbow section.
C Series 1000kva diesel generator specification will be good for your operation.
C Series 1000 kVA DG Set 50Hz Specification | |||
Generator Model | BP-C1000 | Engine Model | Cummins KTA38-G2A (CCEC) |
Standby Power | 1000kVA/800kW | Prime Power | 910kVA/728kW |
Frequency | 50Hz | Rotational Speed | 1500rpm |
Engine Specification for C Series 1000 kVA DG Set 50Hz | |||
Governor | Electronic | Weight | 3719KG |
No. of Cylinders | 12 | Aspiration | Turbocharged & Aftercooled |
Displacement | 38L | Fuel System | Direct Injection Cummins PT |
Hourly Fuel Consumption (100% Output Power) | 191L | Total System Oil Capacity | 135.1L |
Power Range | 813-895kW | Horse Power Range | 1090-1200 |
Cummins KTA38 series engines are all with features as compact size, low fuel consumption, low vibration, low noise, low maintenance, high power output, high parts commonality & long service life, providing powered diesel gensets with great transient response, wide application, high economic efficiency & high reliability and meeting the medium or large power (prime or standby) demand on mining, hospitals, marines, military camps, factories, islands and other fields. As a leading manufacturer of power equipment, Cummins serves customers with International Warranty Services (IWS) in approximately 190 countries and territories through a network of more than 600 company-owned and independent distributor locations and approximately 7,400 dealer locations.
Battery & charger: with 4 maintenance free batteries (200AH) and one DC battery charger (24V), to support genset with reliable starting power supply;
Dimension: 4410mm*1720mm*2170mm (Open type); 6050mm*2430mm*2580mm (20FT Containerized type)
Weight: 7359 kg (Open type); 10260 kg (20FT Containerized type)
If the environment where diesel generator sets C Series 1000kva diesel generators are used requires quietness, then you must purchase silent diesel generator for home use.
There are many types of generator sets, and there are different types of generator sets according to different standards. 1. Divided by power source: diesel generator sets, gas generator sets, gasoline generator sets, wind generator sets, solar generator sets, hydroelectric generator sets, coal-fired generator sets, etc. 2. Electric energy mode: According to the converted electric energy mode, i...more