C Series 125 kVA DG Set 50Hz

- Bidirection Power
- Cummins China
- 30 - 45 days
- 1000 sets
C Series 125 kVA DG Set 50Hz is powered by Cummins diesel engine 6BTA5.9-G2 which has many features as compact size, low fuel consumption, low vibration, low noise, low maintenance, high parts commonality & long service life, providing powered diesel gensets with great transient response, wide application, high economic efficiency & high reliability and meeting the small or medium power (prime or standby) demand on residential use, small shops, small projects and other fields. Cummins serves customers with International Warranty Services (IWS).Analysis of common causes of loss of excitation of silent dg generator set。
Analysis of common causes of loss of excitation of silent dg generator set
With the increase of people’s awareness of environmental protection, silent dg generator sets are becoming more and more popular. Its application fields are very wide and the utilization rate is very high. Due to various reasons, silent dg generator sets will have various failures, including loss of magnetism. It is the most common one. Once the silent generator set loses its magnetization, it will not be able to generate electricity normally, which is no small trouble for customers. Therefore, we are here to summarize some common reasons for the loss of magnetism of silent engine generator sets.
1. The silent diesel engine generator set is parked for a long time and will not be used for maintenance. If the equipment is idle, the necessary maintenance work must be continued.
2. The environment where the silent dg set is placed is harsh, humid, dusty, and corrosive. Equipment operators must do a good job in cleaning the surrounding environment of the equipment to prevent dust and water vapor from entering the equipment.
3. The silent generator set does not cut off the load when it is in use.
4. The silent dg genset suddenly increases the load and the shutdown is easy to lose magnetism.
The above are the common reasons and solutions for the loss of magnetization of silent generator sets listed by Bidirection Power. Summarizing the reasons for loss of magnetism, Bidirection Power believes that the reason for the loss of magnetism of silent generator sets is due to some of our users' usual operations. Errors, and do not maintain them at the same time. Here to remind everyone that in order to ensure the normal use of your super silent diesel generator and extend its service life, please be sure to operate it correctly and pay attention to maintenance.
We Bidirection Power Technology take C series 125 kVA DG set for example as following specification:
C Series 125 kVA DG Set 50Hz Specification | |||
Generator Model | BP-C125 | Engine Model | Cummins 6BTA5.9-G2 (DCEC) |
Standby Power | 125kVA/100kW | Prime Power | 113kVA/90kW |
Frequency | 50Hz | Rotational Speed | 1500rpm |
Engine Specification for C Series 125 kVA DG Set 50Hz | |||
Governor | Electronic | Weight | 435KG |
No. of Cylinders | 6 | Aspiration | Turbocharged & Aftercooled |
Displacement | 5.9L | Fuel System | BYC PB Direct Injection |
Hourly Fuel Consumption (100% Output Power) | 31L | Minimum Required Oil Capacity | 16.4L |
Power Range | 106-116kW | Horse Power Range | 142-155 |
Cummins 6BTA series engines are all with features as compact size, low fuel consumption, low vibration, low noise, low maintenance, high parts commonality & long service life, providing powered diesel generator sets with great transient response, wide application, high economic efficiency & high reliability, and meeting the small or medium power (prime or standby) demand on residential use, small shops, small projects and other fields. As a leading manufacturer of power equipment, Cummins serves customers with International Warranty Services (IWS) in approximately 190 countries and territories through a network of more than 600 company-owned and independent distributor locations and approximately 7,400 dealer locations.
Dimension: 2400mm*950mm*1530mm (Open type); 2980*980*1585mm (Silent type)
Weight: 1220 kg (Open type); 1710 kg (Silent type)
If you have any other special requests for cummins slient dg generator set, pls feel free to contact us, we will support you at any time.
There are many types of generator sets, and there are different types of generator sets according to different standards. 1. Divided by power source: diesel generator sets, gas generator sets, gasoline generator sets, wind generator sets, solar generator sets, hydroelectric generator sets, coal-fired generator sets, etc. 2. Electric energy mode: According to the converted electric energy mode, i...more