C Series 413 kVA DG Set 50Hz

- Bidirection Power
- Cummins China
- 30 - 45 days
- 1000 sets
C Series 413 kVA DG Set 50Hz is powered by Cummins diesel engine 6ZTAA13-G3 which has many features as compact size, low fuel consumption, low vibration, low noise, low maintenance, high power output, high parts commonality & long service life, providing powered diesel gensets with great transient response, wide application, high economic efficiency & high reliability and meeting the medium or large power (prime or standby) demand on mining, hospitals, marines, military camps, factories, islands and other fields. Cummins serves customers with International Warranty Services (IWS).How to deal with the mixing of oil and fuel in silent dg generator set?
Silent dg genset have become the object of competition for people to buy because of their unique advantages. In the process of use, everyone must observe their power operation. As the main source of power for silent generator sets: oil and fuel, we need to remind everyone that the two cannot be mixed. Once mixed, it means that there is a problem with the sealing of the silent generator set. Then, if the two are mixed Phenomenon, how should we deal with it? And listen to Bidirection Power Technology to tell you how to deal with the mixing of oil and fuel in silent dg generator set C Series 413 kVA DG Set 50Hz?
When the silent dg generator set oil and fuel are mixed, the following methods can be used to eliminate:
1. The pump membrane of the oil transfer pump is rotten or degumming, so that the diesel engine genset oil flows into the oil pan and mixes with the engine oil. Remove the oil transfer pump, and add corresponding pressure to the oil inlet and outlet pipes on the oil pump test bench. If no engine diesel leakage is found, the oil transfer pump is intact.
2. The opening pressure of the fuel injector is low, and the atomization is poor, so that the diesel fuel flows into the oil pan along the cylinder wall to mix with the oil. Remove the fuel injector and test it on the high-pressure fuel pump test bench. If the opening pressure of the fuel injector meets the requirements and the atomization is good, the fuel injector is intact. Otherwise, repair or replace it.
3. The front end of the fuel injection pump is leaking, that is, the front end of the fuel injection pump is ineffective. Remove the inspection hole cover of the gear chamber cover. If a large amount of diesel is sprayed from behind the drive gear of the fuel injection pump, it can be concluded that the diesel is leaking into the fuel from the fuel injection pump. The bottom shell is mixed with engine oil. Disassemble the fuel injection pump and test on the high pressure fuel pump test bench. It is found that the oil seal at the front gear journal of many fuel injection pumps is deformed, a large amount of diesel oil is leaked, and the oil seal seat has a disassembled gear, and the trace (indentation) of the special tool screw is used to make the oil seal The seat and oil seal are deformed, causing diesel oil leakage. Finally, replace the fuel injection pump and the failure can be resolved.
The above three points are the response methods of silent dg generator sets under the mixture of oil and fuel introduced by Bidirection Power Technology. Generally, this situation is difficult to find in the early stage, so everyone must pay attention to regular maintenance of silent generator sets. At the same time, it is necessary to carefully investigate during daily maintenance, find and solve the problem in time, so that it will not cause too much impact.
C Series 413 kVA DG Set 50Hz Specification | |||
Generator Model | BP-C413 | Engine Model | Cummins 6ZTAA13-G3 (DCEC) |
Standby Power | 413kVA/330kW | Prime Power | 375kVA/300kW |
Frequency | 50Hz | Rotational Speed | 1500rpm |
Engine Specification for C Series 413 kVA DG Set 50Hz | |||
Governor | Electronic | Weight | 1200KG |
No. of Cylinders | 6 | Aspiration | Turbocharged & Charge air cooled |
Displacement | 13L | Fuel System | BYC PD |
Hourly Fuel Consumption (100% Output Power) | 76.5L | Total System Oil Capacity | 45.42L |
Power Range | 340-380kW | Horse Power Range | 456-510 |
Cummins 6ZTAA series engines are all with features as compact size, low fuel consumption, low vibration, low noise, low maintenance, high parts commonality & long service life, providing powered diesel generator sets with great transient response, wide application, high economic efficiency & high reliability, and meeting the small or medium power (prime or standby) demand on residential use, small shops, small projects and other fields. As a leading manufacturer of power equipment, Cummins serves customers with International Warranty Services (IWS) in approximately 190 countries and territories through a network of more than 600 company-owned and independent distributor locations and approximately 7,400 dealer locations.
Battery & charger: with 2 maintenance free batteries (150AH) and one DC battery charger (24V), to support genset with reliable starting power supply;
Dimension: 3110mm*1360mm*1920mm (Open type); 4570*1420*2200mm (Silent type)
Weight: 3000 kg (Open type); 4230 kg (Silent type)
The above is the specification for C Series 413 kVA DG Set 50Hz,to deal with the mixing of oil and fuel in silent dg generator set, our engineer will send you more instruction for product operation manual once you buy standby generator C Series 413 kVA DG Set 50Hz.
There are many types of generator sets, and there are different types of generator sets according to different standards. 1. Divided by power source: diesel generator sets, gas generator sets, gasoline generator sets, wind generator sets, solar generator sets, hydroelectric generator sets, coal-fired generator sets, etc. 2. Electric energy mode: According to the converted electric energy mode, i...more